The capacitive fuel level sensor ESCORT TD-BLE is designed to measure the level of light petroleum derivatives in the tanks of vehicles, machinery units and storage tanks.

Request a Quote
Details

The capacitive fuel level sensor ESCORT TD-BLE (hereinafter - the ‘Sensor’, ‘Device’ or “TD-BLE”) is designed to measure the level of light petroleum derivatives in the tanks of vehicles, machinery units and storage tanks.
The Device converts the fuel level readings into digital code. The Sensor transmits the level readings via Bluetooth (LE) channel in accordance with the ESCORT BLE protocol.
The Device has an autonomous power supply which is a replaceable lithium thionyl chloride non-rechargeable battery that does not require any maintenance. Applicable in explosive zones of 0, 1 and 2 (IEC 60079-10-1-2011) classes IIA JIB 31610-10-1-2022 as per explosion proof mark.

Shipping & Returns

Product Specifications

GENERAL SPECIFICATIONS
Margin of error Not more than 1% of MRV (maximum range value)
Operating mode Digital
DIGITAL OUTPUTS
Communication interface Bluetooth LE (BLE)
Data exchange protocol Escort BLE
Range Not less than 10 m (under normal operating conditions without interference or obstacles when working with the base)
Advertising package transmission interval 3 s
Receiver sensitivity / Transmitter power -96 dBm / 4 dBm
PROTECTION & SAFETY
Ingress protection marking IP69S
Electric shock resistance rating Class III
Explosion protection type «ia» level intrinsically safe circuit
Explosion proof mark 0Ex ia IIB T6 X
Operable explosive liquid categories IIA, IIB
Operable explosive zones Zones 0, 1 and 2 (IEC 60079–10–1–2013)
OPERATING CONDITIONS
Operating temperature range -45 °C to +50 °C
Extreme operating temperature range -60 °C to +85 °C
Operating atmospheric pressure 84 to 106.7 kPa
Extreme atmospheric pressure 57 to 110 kPa
ELECTRICAL CHARACTERISTICS
Battery voltage Not more than 3.6 V
Operating frequencies 2.402 – 2.480 GHz
MEASUREMENT PARAMETERS
Angle measurement range 0° to 180°
Angle measurement margin of error ±5°
PHYSICAL SPECIFICATION
Dimensions (Mark I) 87.5 × (L + 39) mm
Dimensions (Mark II & III) 97 × 88 × (L + 33) mm
Modifiable length of measurement part Vehicles: 150–2500 mm; Stationary tanks: 150–6000 mm (see sticker in datasheet)
Weight Not more than 0.5 + 0.4 × L kg
NOTES
MRV definition Maximum value of measurement range (1023 or 4095)
Tilt angle reference Relative to the horizontal plane
L definition Measurement part length in millimeters
Accelerometer note Weight specification applies to variation with accelerometer